Background from the literature

On-line mass spectrometry was develop to solve some of the limitations and problem that develop from off-line analysis, such as evaporation and chemical reactions of particles in the filters during long analysis time. On-line Mass spectrometry solves these problems through the collection and analysis of aerosol particles in real time. On-line instruments are very portable and allow for spatial variability to be examined. These portable instruments can be put on many different platforms such as boats, planes, and mobile platforms (e.g. car trailers). An example of this is in the picture at the beginning with the instrumentation attached to an aircraft. Like off-line, on-line mass spectrometry has many different type of instruments, which can be broken up into two types; instruments that measures the chemistry of the particle ensemble (bulk measurement) and those that measure the chemistry of individual particles (single-particle measurement). Thus based on analytical need different instrumentation is used in analysis of the aerosol particles.

Aerosol mass spectrometry is the application of mass spectrometry to the analysis of the composition of aerosol particles. Aerosol particles are defined as solid and liquid particles suspended in a gas (air), with size range of 3 nm to 100 μm in diameter and are produced from natural and anthropogenic sources, through a variety of different processes that include wind-blown suspension and combustion of fossil fuels and biomass. Analysis of these particles is important owing to their major impacts on global climate change, visibility, regional air pollution and human health. Aerosols are very complex in structure, can contain thousands of different chemical compounds within a single particle, and need to be analysed for both size and chemical composition, in real-time or off-line applications. Off-line mass spectrometry is performed on collected particles, while on-line mass spectrometry is performed on particles introduced in real time.

The Society recognizes achievements and promotes academic research through four annual awards. The Biemann Medal and the John B. Fenn Award for a Distinguished Contribution in Mass Spectrometry both are awarded in recognition of singular achievements or contributions in fundamental or applied mass spectrometry, with the Biemann Medal being focused on individuals who are early in their careers. The Ronald A. Hites Award is awarded for outstanding original research demonstrated in papers published in the Journal of the American Society for Mass Spectrometry. The Research Awards are given to young scientists in mass spectrometry, based on the evaluation of their proposed research. The Fellows of ASMS are awarded to individuals in recognition for their scientific contribution to mass spectrometry and for their contribution to the ASMS community. Journal of the American Society for Mass Spectrometry Measuring Mass: From Positive Rays to Proteins The past presidents of ASMS are:

Sources: en.wikipedia.org

Reference notes

The major cell-matrix adhesion receptors are integrins and therefore the adhesome of cell-matrix adhesion is referred to as the integrin adhesome. Cell-cell adhesion is primarily mediated by cadherin receptors and therefore the adhesome of cell-cell adhesion is referred to as the cadherin adhesome or cadhesome. The first attempts to establish the set of proteins that participate directly ('bona fide' adhesome components) or affect indirectly ('associated' adhesome components) cell adhesion were based on mining of the primary research literature, and resulted in approximately 200 protein in either integrin or cadherin adhesomes. Later, unbiased proteomic approaches utilizing mass spectrometry have detected hundreds more proteins associated with integrin adhesions. However, a comparison of multiple proteomic studies of the integrin adhesome of fibroblasts attached to fibronectin found only 60 proteins common to all studies. Humphries and co-workers named these 60 proteins the 'consensus integrin adhesome'.

Laser microprobe mass spectrometer Particulate matter sampler Aerosol impaction Particle size analysis Hartonen, Kari; Laitinen, Totti; Riekkola, Marja-Liisa (2011). "Current instrumentation for aerosol mass spectrometry". TrAC Trends in Analytical Chemistry. 30 (9): 1486–1496. doi:10.1016/j.trac.2011.06.007. ISSN 0165-9936. Centre for Atmospheric Science TOF-AMS resources Q-AMS resources List of publications using all versions of the AMS Glossary of AMS terms

Solid-liquid extraction based ambient ionization is based on the use of a charged spray, for example electrospray to create a liquid film on the sample surface. Molecules on the surface are extracted into the solvent. The action of the primary droplets hitting the surface produces secondary droplets that are the source of ions for the mass spectrometer. Desorption electrospray ionization (DESI) is one of the original ambient ionization sources and uses an electrospray source to create charged droplets that are directed at a solid sample. The charged droplets pick up the sample through interaction with the surface and then form highly charged ions that can be sampled into a mass spectrometer. Desorption atmospheric pressure photoionization (DAPPI) is a solid-liquid extraction ambient ionization method that enables the direct analysis of samples deposited on surfaces by means of a jet of hot solvent vapour and ultraviolet light. The hot jet thermally desorbs the sample from a surface and the vaporized sample is ionized by a vacuum ultraviolet light and consequently sampled into a mass spectrometer.

Solid-liquid extraction based ambient ionization is based on the use of a charged spray, for example electrospray to create a liquid film on the sample surface. Molecules on the surface are extracted into the solvent. The action of the primary droplets hitting the surface produces secondary droplets that are the source of ions for the mass spectrometer. Desorption electrospray ionization (DESI) is one of the original ambient ionization sources and uses an electrospray source to create charged droplets that are directed at a solid sample. The charged droplets pick up the sample through interaction with the surface and then form highly charged ions that can be sampled into a mass spectrometer. Desorption atmospheric pressure photoionization (DAPPI) is a solid-liquid extraction ambient ionization method that enables the direct analysis of samples deposited on surfaces by means of a jet of hot solvent vapour and ultraviolet light. The hot jet thermally desorbs the sample from a surface and the vaporized sample is ionized by a vacuum ultraviolet light and consequently sampled into a mass spectrometer.

Sources: en.wikipedia.org

Network